Have you checked the main website?
The answers to many questions are there!


Pavingexpert
The Brew Cabin
Paving, Drainage and
Hard-landscaping in
Britain and Ireland

Search Members Help

» Welcome Guest           [ Log In :: Register ]

ruler

 

[ Track this topic :: Email this topic :: Print this topic ]

reply to topic start new topic
Topic: Clay under permeable block paving, Advice on what method to build pbp drive< Next Oldest | Next Newest >
Clarely
Offline

Apprentice




Group: Members
Posts: 3
Joined: June 2017
Posted: 20 June 2017,19:43 QUOTE

Hi - we've dug a test pit 400mm x 400mm x 400mm & filled it full of water, after 24 hours the water was still at the original level.  So my question is, with the council saying, yes build Permeable Block Paving drive (so we can have a dropped kerb), will it actually work if we use 4-20 sub base and then 6mm on top of that?  Or will clay like this make it impossible?

And if it's not a good idea, then what do I do?  Any ideas would be great.

We're putting a linear drain in at the bottom of the 1:8 slope.  I'm worried that building it as permeable will just mean that water sits underneath it & then wells up out of the blocks.


--------------
Clarely
Back to top
Profile Personal Message 
Clarely
Offline

Apprentice




Group: Members
Posts: 3
Joined: June 2017
Posted: 22 June 2017,09:20 QUOTE

I'm wondering about using MOT1 and sand rather than 4/20 and 6mm.  Any thoughts from anyone please?

--------------
Clarely
Back to top
Profile Personal Message 
seanandruby
Offline

sean




Group: Moderator
Posts: 4735
Joined: June 2006
Posted: 22 June 2017,10:41 QUOTE

here9
There is loads of detailed information on the pemeable and suds index pages. It may be you will have to connect to the swd as a last resort.


--------------
sean
Back to top
Profile Personal Message 
Tony McC
Offline

Site Agent




Group: Moderator
Posts: 10960
Joined: July 2004
Posted: 22 June 2017,10:59 QUOTE

DTp1 (the term we should be using for MoT1) is NOT suyitable for a permeable pavement. It just doesn;t have the permeability nor the void space to provide storage capacity.

If ground tests show the sub-grade is, effectively, impermeable, the council may have to consent to you using a standard (ie: non-permeable) construction or a highly compicated overspill version of a permeable pavement, but only they can decide.

Document the standing water and present it to the council. It could well be easier for them to take the 150 quid or so from you and grant permission for the standard construction.


--------------
Site Agent - Pavingexpert
Back to top
Profile Personal Message WEB 
Clarely
Offline

Apprentice




Group: Members
Posts: 3
Joined: June 2017
Posted: 22 June 2017,11:12 QUOTE

Thanks.  My neighbours have permeable, but also said all their water goes into the sewers!  Wondered if it had been constructed as permeable, but it just doesn't drain.  Very odd.

--------------
Clarely
Back to top
Profile Personal Message 
Tony McC
Offline

Site Agent




Group: Moderator
Posts: 10960
Joined: July 2004
Posted: 22 June 2017,13:06 QUOTE

There is an option for permeable with overspill, as I mentioned, but only the council can grant PP for such a construction.

In essence, the collected surface water is first given a chance to escape to ground but if the volume of water is greater than the ground can cope with, then the excess 'spills over' and goes into a sewer.


--------------
Site Agent - Pavingexpert
Back to top
Profile Personal Message WEB 
5 replies since 20 June 2017,19:43 < Next Oldest | Next Newest >

[ Track this topic :: Email this topic :: Print this topic ]

 
reply to topic start new topic
Quick Reply: Clay under permeable block paving

Do you wish to enable your signature for this post?
Do you wish to enable emoticons for this post?
Track this topic
View All Emoticons
View iB Code


ruler

ruler